Genie SX-125 XC Telescopic Boom Lift Parts

Keeping your Genie SX-125 XC in peak operating condition starts with the right parts and a solid maintenance routine. Ensure your boom lift stays in top shape with high-quality hydraulic filters, oil filters, load cells and more. The SX-125 XC offers a working height up to 131 feet, dual-capacity platform zones, and rugged off-road performance—perfect for heavy-duty construction and industrial sites. Don’t forget to stay on top of your maintenance—secure the parts you need to keep your Genie SX-125 XC running smoothly!

Walk-Around Inspection

  • Inspect boom, jib, platform, and hydraulic cylinders for damage or leaks
  • Check all safety decals, platform labels, and guardrails for legibility
  • Inspect tires, lug nuts, and axles—verify correct torque and inflation
  • Check fluid levels: engine oil, hydraulic fluid, coolant, DEF, and fuel
  • Inspect platform controls, switches, and display panel for damage
  • Ensure lanyard anchor points are clean and securely attached

Daily Maintenance

  • Check and top off engine oil, coolant, fuel, and hydraulic fluid
  • Inspect radiator and oil cooler fins for dust or blockage
  • Drain water from the fuel/water separator
  • Test platform and ground emergency stop buttons
  • Clean battery terminals and inspect for corrosion

Every 50 Hours

  • Lubricate boom pivot points and platform rotating components
  • Inspect electrical wiring, alarms, and platform tilt sensors
  • Check engine belts for wear or tension loss

Every 250 Hours

  • Change engine oil and replace oil filter
  • Inspect and clean engine air intake and filters
  • Check wheel torque and hydraulic lines for leaks or chafing

Every 500 Hours

  • Replace fuel filters and inspect fuel lines
  • Replace hydraulic return filter element
  • Inspect axle movement and pivot function

Every 1,000 Hours

  • Flush and replace hydraulic fluid
  • Replace engine air filter (primary and secondary)
  • Inspect all electrical fuses, breakers, and control circuits

Every 2,000 Hours

  • Flush and refill engine coolant
  • Check DEF filter and emissions sensors (Perkins 854F engines)
  • Inspect steering, brake, and control linkages

Annual Maintenance

  • Verify boom angle and length sensors using platform display
  • Test emergency lowering and platform recovery switch
  • Inspect platform overload system and fault indicators

As-Needed Maintenance

  • Replace tires, platform parts, or broken safety switches
  • Clean radiator, DEF tank filter, and clogged breathers
  • Recharge or replace worn-out batteries
  • Reset platform level sensors or software if alerts appear

Final Maintenance Recommendations

Regular maintenance keeps your Genie SX-125 XC operating safely and efficiently. For a full range of Genie parts, explore our extensive EquipmentShare parts catalog. If you can’t find the part you need, reach out to our parts experts for a custom order.

Filter products

The highest price is $1,485.88
$
$

19 Products